RFI: How to Troubleshoot Buzzing, humming, high-pitched whines, static, turn on/turn off spikes, signal loss - all examples of interference that affects the performance of sensitive electronics. The key to understanding how to troubleshoot is to understand the causes.
— By John Payne
An example of transient waveform. |
Noise sources on a boat are often classified as radio
frequency interference (RFI) or electromagnetic interference (EMI).
They are major enemies of electronic systems, corrupting your GPS
position fixes, degrading radio communications and causing general
electronics’ performance problems.
RFI is essentially interference and noise that is superimposed as
a disturbance or voltage transient either on the electrical power
supply or the data and signal lines. This is then processed along
with the good data to corrupt or degrade the processed information.
Transient or Induced?
The voltage transient is probably the most damaging and comes from
many sources. The best-known effect is the corruption of GPS and
Loran data where the power is taken off an engine starting battery.
When a significant load is applied to the battery, there is a momentary
voltage drop creating what is often called a brown out condition
and then is followed by a voltage increase. This low-voltage disturbance
can exceed 100 volts in some cases, damaging power supplies, wiping
memories or corrupting the data. The same applies to two battery
systems where the house bank supplies items such as electric toilets
and other heavy current draw equipment. A starting battery voltage
can have a 3 to 4-volt dip on starting. The variation or interruption
of current in the equipment power conductor also causes transients.
Induced interference is the second common RFI noise source. Electrical
fields are radiated from cables and equipment and this is induced
into other closely located cables or equipment. The most common
causes of this are cables running parallel or within the same cable
bundle, known as mutual coupling. Always run power supply cables
and data cables separately and make cable crossovers at 90°.
In particular run power cables to sensitive equipment separate to
main power cables to reduce inductive and capacitive coupling to
signal conductors.
Common Sources
Noise occurs in different frequency ranges and similarly, equipment
may only be prone to problems within a particular frequency range.
Multiple noise sources can cause a gradual degradation of electronics
components and when the cumulative effects reach a certain point,
the devices fail.
• Arcing Noise. These are repetitive
spikes that are caused by commutators and sparking of brushes. The
brushes on any alternator, particularly if dirty, can cause sparking
and noise. Charging systems commonly cause this or when loose connections
exist. The most common cause is loose or poor engine return paths
for alternators, when the negative path arcs across points of poor
electrical contact. This is also caused by ignition systems from
distributors and spark plugs being impressed on a DC system, often
through radiation to adjacent cables. When troubleshooting, always
determine what is running at the same time.
• Induced Coupling Interference.
Wiring that is installed in parallel with others can suffer from
inductive coupling interference causing buzzes and humming sounds
on the radio. This occurs like a transformer with a single turn
primary and secondary coil, with the magnetic effects causing the
induction. Low ground impedance and unbalanced circuits are the
most prone with serial data, multi-cable control and co-axial cables
being the most susceptible ones. It’s important to keep signal
cables from running in parallel with main power wiring. When troubleshooting,
always determine what is running at the time as this impacts which
cables are involved and will help localize the problem area.
• Ripple Noise. Ripple is created
in any rectifier bridges (diode, silicone-controlled rectifier (SCR),
etc) such as alternators, chargers, fluorescent lights and inverters.
It’s usually a high-pitched whine. Good quality equipment
has suppressed electronics. Ripple badly degrades communications’
audio quality. When troubleshooting, again determine which lights
are on, or whether chargers or engines are running.
A distance of at least 6" (15cm) should
separate signal cables from power-carrying wires. |
• Static Charges. These
have a number of sources. External charge interference arises due
to static build-ups in sailboat rigging. On reaching a certain voltage
level, the static charge discharges to ground to cause interference.
Another common cause is when dry, offshore winds occur and a static
charge builds up on fiberglass decks. The problem is prevalent on
large fiberglass yachts with large deck areas. A lightning protection
system can ground these charges. Engine and shaft charges also cause
interference and this can arise due to static build-ups, both induced
and those due to moving parts in the engine. The static charge discharges
to ground to cause interference. Shaft interference can arise due
to static build-ups on propeller shafts. The static will cause interference
when it discharges to ground on reaching a high voltage level.
• Surge (electromagnetic pulse). This
can be caused by lightning activity. Pulses can be induced into
electrical wiring and aerials.
• Spikes. Turn-on spike results from
the initial charging of power supply input filters on power supplies.
Turn-off spikes arise when reactive loads are switched and the magnetic
fields collapse on inductive loads, such as transformers, relay
or contactor coils, solenoid coils, pump motors, etc. MOV suppressors
are often put across the coils.
• Solar Activity. This is caused
by ionospheric and solar or sun spot activity. Usually it results
in signal losses or major corruption. When troubleshooting this
condition, always check whether storms are in the area.
Troubleshooting
Once sources are defined, RFI troubleshooting is the relatively
simple method of locating the noise source. The listed causes must
be verified one by one to eliminate them. It’s a matter of
logic and the systematic switching off of each device to locate
the noise source. When the noise stops, the cause is located. A
simple process of elimination, although it isn’t always that
easy. In many cases, it may consist of identifying two or more sources
that are overlaid to cause a cumulative noise effect. Some RFI noise
is simply intermittent, such as static discharges or lightning pulses,
which may not even be visible locally.
What tools do you need? A small, cheap battery-powered AM radio
is a good tool for tracking down and sniffing out radiated sources
of noise on board, with static causes being easily picked up. Passing
it close to the cables or equipment is the method used. Some noise
is simply related to time of day and interference from solar activity
and ionosphere factors on radios are sources that must be considered.
These may affect GPS, SSB and HAM radio and satellite communications
all simultaneously, giving the appearance of some greater problem.
If you have determined that RFI is around noise and dust, you may
already have the answer.
When troubleshooting a GPS or radio, first disconnect the antenna
and, if the noise continues, it’s probably caused by the electrical
system. If RFI increases when the GPS or radio aerial is reconnected,
then the cause may be atmospheric or from some other emission or
is being picked up from the antenna feed cables. It’s important
to understand that RFI may originate from more than one path, so
ensure all possibilities are investigated.
Metallic Sounds
Ticking on the radio is a common problem. When the ticking noise
varies with the speed of the engine, then you are probably experiencing
ignition noise or alternator based causes. Usually this only affects
the power wire for the equipment. Sources of this noise are usually
the distributor, the ignition coil, spark plug wires and spark plugs.
If ignition noise is identified, move the power wire as far as practicable
from any of these sources. If this does not improve things, then
check all of these components. Also, check that plug wires and spark
plugs are RFI shielded.
Suppression Methods
There are a number of methods that can be used to reduce or eliminate
interference. The use of shielded cables along with proper installation
is one. The use of suppressors, such as a filter or capacitor installed
close to the noisy equipment is common and this effectively short
circuits noise in the protected frequency range. Filters may take
a number of forms and suppressor capacitors may need to be installed
on alternators. Cable separation is another major suppression method.
| Proper Grounding |
By John Payne
A distance of at least 6" (15cm)
should separate signal cables from power-carrying wires.
|
The proper grounding of electronic equipment
is essential for optimum performance. Most RFI problems, such
as noises, hums, buzzes, interference or cross talk, etc.
are, in many cases, caused by bad electronic grounding.
Ground signals carry currents and currents
run through the wires. If there is any difference in voltage
between the two ground points, this causes current flow and
problems. Currents that flow through the various grounds are
known as ground loops. The ground in electronics is a reference
voltage point for all signals equal to 0 volts. To prevent
ground loops, all signal grounds should be connected to one
common point. Cable shields are designed to protect against
interference from unknown or unspecified sources. The effectiveness
of shields is measured in terms of transfer impedance. This
is a measure of effectiveness in capturing the interference
field and preventing it from reaching the conductor pairs
inside. Data cables also have shields that are made from a
foil-polymer laminate tape or have layers of braiding. These
also may have a drain wire installed to enable termination
of the screen to ground. Most equipment manufacturers also
specify the termination of shields to ground. Never ground
at both ends. Always ground one end only and, typically, this
is at the equipment end. In many cases, shields are not connected
at all, so check and connect them, as it may be a source of
RFI.
|
|